mirror of
https://github.com/pybind/pybind11.git
synced 2024-11-26 23:22:01 +00:00
baa540ec34
* Support free-threaded CPython (PEP 703) Some additional locking is added in the free-threaded build when `Py_GIL_DISABLED` is defined: - Most accesses to internals are protected by a single mutex - The registered_instances uses a striped lock to improve concurrency Pybind11 modules can indicate support for running with the GIL disabled by calling `set_gil_not_used()`. * refactor: use PYBIND11_MODULE (#11) Signed-off-by: Henry Schreiner <henryschreineriii@gmail.com> * Address code review * Suppress MSVC warning * Changes from review * style: pre-commit fixes * `py::mod_gil_not_used()` suggestion. * Update include/pybind11/pybind11.h --------- Signed-off-by: Henry Schreiner <henryschreineriii@gmail.com> Co-authored-by: Henry Schreiner <HenrySchreinerIII@gmail.com> Co-authored-by: pre-commit-ci[bot] <66853113+pre-commit-ci[bot]@users.noreply.github.com> Co-authored-by: Ralf W. Grosse-Kunstleve <rwgk@google.com>
132 lines
4.6 KiB
C++
132 lines
4.6 KiB
C++
/*
|
|
tests/pybind11_tests.cpp -- pybind example plugin
|
|
|
|
Copyright (c) 2016 Wenzel Jakob <wenzel.jakob@epfl.ch>
|
|
|
|
All rights reserved. Use of this source code is governed by a
|
|
BSD-style license that can be found in the LICENSE file.
|
|
*/
|
|
|
|
#include "pybind11_tests.h"
|
|
|
|
#include "constructor_stats.h"
|
|
|
|
#include <functional>
|
|
#include <list>
|
|
|
|
/*
|
|
For testing purposes, we define a static global variable here in a function that each individual
|
|
test .cpp calls with its initialization lambda. It's convenient here because we can just not
|
|
compile some test files to disable/ignore some of the test code.
|
|
|
|
It is NOT recommended as a way to use pybind11 in practice, however: the initialization order will
|
|
be essentially random, which is okay for our test scripts (there are no dependencies between the
|
|
individual pybind11 test .cpp files), but most likely not what you want when using pybind11
|
|
productively.
|
|
|
|
Instead, see the "How can I reduce the build time?" question in the "Frequently asked questions"
|
|
section of the documentation for good practice on splitting binding code over multiple files.
|
|
*/
|
|
std::list<std::function<void(py::module_ &)>> &initializers() {
|
|
static std::list<std::function<void(py::module_ &)>> inits;
|
|
return inits;
|
|
}
|
|
|
|
test_initializer::test_initializer(Initializer init) { initializers().emplace_back(init); }
|
|
|
|
test_initializer::test_initializer(const char *submodule_name, Initializer init) {
|
|
initializers().emplace_back([=](py::module_ &parent) {
|
|
auto m = parent.def_submodule(submodule_name);
|
|
init(m);
|
|
});
|
|
}
|
|
|
|
void bind_ConstructorStats(py::module_ &m) {
|
|
py::class_<ConstructorStats>(m, "ConstructorStats")
|
|
.def("alive", &ConstructorStats::alive)
|
|
.def("values", &ConstructorStats::values)
|
|
.def_readwrite("default_constructions", &ConstructorStats::default_constructions)
|
|
.def_readwrite("copy_assignments", &ConstructorStats::copy_assignments)
|
|
.def_readwrite("move_assignments", &ConstructorStats::move_assignments)
|
|
.def_readwrite("copy_constructions", &ConstructorStats::copy_constructions)
|
|
.def_readwrite("move_constructions", &ConstructorStats::move_constructions)
|
|
.def_static("get",
|
|
(ConstructorStats & (*) (py::object)) & ConstructorStats::get,
|
|
py::return_value_policy::reference_internal)
|
|
|
|
// Not exactly ConstructorStats, but related: expose the internal pybind number of
|
|
// registered instances to allow instance cleanup checks (invokes a GC first)
|
|
.def_static("detail_reg_inst", []() {
|
|
ConstructorStats::gc();
|
|
return py::detail::num_registered_instances();
|
|
});
|
|
}
|
|
|
|
const char *cpp_std() {
|
|
return
|
|
#if defined(PYBIND11_CPP20)
|
|
"C++20";
|
|
#elif defined(PYBIND11_CPP17)
|
|
"C++17";
|
|
#elif defined(PYBIND11_CPP14)
|
|
"C++14";
|
|
#else
|
|
"C++11";
|
|
#endif
|
|
}
|
|
|
|
PYBIND11_MODULE(pybind11_tests, m, py::mod_gil_not_used()) {
|
|
m.doc() = "pybind11 test module";
|
|
|
|
// Intentionally kept minimal to not create a maintenance chore
|
|
// ("just enough" to be conclusive).
|
|
#if defined(__VERSION__)
|
|
m.attr("compiler_info") = __VERSION__;
|
|
#elif defined(_MSC_FULL_VER)
|
|
m.attr("compiler_info") = "MSVC " PYBIND11_TOSTRING(_MSC_FULL_VER);
|
|
#else
|
|
m.attr("compiler_info") = py::none();
|
|
#endif
|
|
m.attr("cpp_std") = cpp_std();
|
|
m.attr("PYBIND11_INTERNALS_ID") = PYBIND11_INTERNALS_ID;
|
|
// Free threaded Python uses UINT32_MAX for immortal objects.
|
|
m.attr("PYBIND11_REFCNT_IMMORTAL") = UINT32_MAX;
|
|
m.attr("PYBIND11_SIMPLE_GIL_MANAGEMENT") =
|
|
#if defined(PYBIND11_SIMPLE_GIL_MANAGEMENT)
|
|
true;
|
|
#else
|
|
false;
|
|
#endif
|
|
m.attr("PYBIND11_NUMPY_1_ONLY") =
|
|
#if defined(PYBIND11_NUMPY_1_ONLY)
|
|
true;
|
|
#else
|
|
false;
|
|
#endif
|
|
|
|
bind_ConstructorStats(m);
|
|
|
|
#if defined(PYBIND11_DETAILED_ERROR_MESSAGES)
|
|
m.attr("detailed_error_messages_enabled") = true;
|
|
#else
|
|
m.attr("detailed_error_messages_enabled") = false;
|
|
#endif
|
|
|
|
py::class_<UserType>(m, "UserType", "A `py::class_` type for testing")
|
|
.def(py::init<>())
|
|
.def(py::init<int>())
|
|
.def("get_value", &UserType::value, "Get value using a method")
|
|
.def("set_value", &UserType::set, "Set value using a method")
|
|
.def_property("value", &UserType::value, &UserType::set, "Get/set value using a property")
|
|
.def("__repr__", [](const UserType &u) { return "UserType({})"_s.format(u.value()); });
|
|
|
|
py::class_<IncType, UserType>(m, "IncType")
|
|
.def(py::init<>())
|
|
.def(py::init<int>())
|
|
.def("__repr__", [](const IncType &u) { return "IncType({})"_s.format(u.value()); });
|
|
|
|
for (const auto &initializer : initializers()) {
|
|
initializer(m);
|
|
}
|
|
}
|